PARAMMachine parameter · TABLE (L)
L85

Correction value of alignment deviation Y (Upper face)

Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
What it does

Correction value of alignment deviation X (Upper face)

ex: Alignment deviation correction value on X-axis ey: Alignment deviation correction value on Y-axis Mx: Stylus radius in the X-axis direction (The setting of L3) My: Stylus radius in the Y-axis direction (The setting of L4) Note : The data is set automatically by execution of calibration measurement (on the upper face) with the MMS unit.

Setting
Setting range0 to ±99999999
Unit0.0001 mm/0.00001 in
Program typeM
Takes effectAfter stop of movement
Source

Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 73, 483. Reference and explanation only — not a reproduction of the manual.

Not sure what to set? Ask the Mazatrol assistant →