PARAMMachine parameter · TABLE (L)
L94

X/Y travel distance during EIA-programmed tool measurement

Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
What it does

X/Y travel distance during EIA-programmed tool measurement

The X/Y travel distance can be set during the selection of EIA-programmed fully automatic tool length measurement with the measuring table. 0: Invalid 1: Valid Note : It is invalid to set this parameter under laser tool measuring equipment specifications.

Setting
Setting range0, 1
Unit—
Program typeE
Takes effectImmediate
Source

Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 485. Reference and explanation only — not a reproduction of the manual.