PARAMMachine parameter · TABLE (L)
L95

Offset number auto-setting for EIA-programmed tool measurement

Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
What it does

Offset number auto-setting for EIA-programmed tool measurement

The offset number is auto-set during EIA-programmed tool measurement data setting. 0: Invalid 1: Valid Note : When making the auto-setting function valid, see the description of L96.

Setting
Setting range0, 1
Unit—
Program typeE
Takes effectImmediate
Source

Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 74, 485. Reference and explanation only — not a reproduction of the manual.

Not sure what to set? Ask the Mazatrol assistant →