PARAMMachine parameter · FEED VEL. (M)
M1
Rapid feed rate
Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
What it does
Rapid feed rate
The feed rate for moving each axis under the G00 command during automatic operation The feed rate for moving each axis in either the manual rapid feed mode or the zero-point return mode Note : Initial zero-point return is performed at the feed rate set in parameter M2.
Setting
Setting range0 to 600000
Unitmm/min (°/min)
Program typeM, E
Takes effectAfter stop of movement
Source
Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 77, 505. Reference and explanation only — not a reproduction of the manual.