PARAMMachine parameter · FEED VEL. (M)
M19

FEED VEL. bit settings (5 bits)

Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
Bit settings — M19 is set bit by bit
  1. bit 0

    Transmission of rapid feed rate value to SV69/SV70

    Set whether or not the value of parameter M1 (rapid feed rate) is transmitted to servo parameter at power-on. 0 : Transmit (same as before) 1 : Do not transmit

    Range 0, 1 · Takes effect: At power on

  2. bit 3

    In-position checking method

    0 : NC 1 : Servo

    Range 0, 1 · Takes effect: At power on

  3. bit 4

    Parameter for system internal setting Setting prohibited

  4. bit 5

    Zero-point operation starting position check

    0: No check 1: Alarm if returned from the dog

    Range 0, 1 · Takes effect: At power on

  5. bit 7

    Backlash scheme to be adopted for dog-type returning to zero point

    0 : G01 1 : G00

    Range 0, 1 · Takes effect: At power on

Source

Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 79, 511, 512. Reference and explanation only — not a reproduction of the manual.

Not sure what to set? Ask the Mazatrol assistant →