PARAMMachine parameter · FEED VEL. (M)
M20

FEED VEL. bit settings (8 bits)

Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
Bit settings — M20 is set bit by bit
  1. bit 0

    Rotational direction of the rotation axis (Dynamic offset )

    0: Forward 1: Reverse

    Range 0, 1 · Takes effect: At power on

  2. bit 1

    KOMET tool axis specification

    0: Normal 1: KOMET tool axis

    Range 0, 1 · Takes effect: At power on

  3. bit 2

    Method of jog/rapid feed stopping when the INTELLIGENT SAFETY SHIELD is valid

    0: With the ISS being selected, the stop is delayed by about 140 ms than otherwise. Example : The stop position for combining the tailstock or steady rest will be shifted accordingly. 1: Independently of whether the ISS is selected or canceled, the axis movement will come to a stop in one and the same position. Example : Independently of the ISS, the stop for combining the tailstock or steady rest will occur in one and the same position. Changing the parameter setting from 0 to 1, therefore, must be followed by a readjustment of the combining position.)

    Range 0, 1 · Takes effect: At power on

  4. bit 3

    Current position display of NC steady rest axis

    Select the method of displaying the current position of NC steady rest axis. 0: Display the value considering the reference workpiece zero point (S23) and WPC-Z. 1: Display the same value as the machine position. * This is valid for current position display on the POSITION, VIRTUAL MACHINING and TOOL PATH CHECK displays.

    Range 0, 1 · Takes effect: At power on

  5. bit 4

    Warning check for alarm 67 HI-SPEED SYNCTAP AXIS ALARM

    0: Include 1: Do not include

    Range 0, 1 · Takes effect: At power on

  6. bit 5

    Multi-axis integrated type amplifier specification

    0: Normal 1: Multi-axis integrated type amplifier

    Takes effect: At power on

  7. bit 6

    Switching between zero-point shift amount and grid shift amount

    This parameter determines the use of parameter M16. 0: Use parameter M16 for zero-point shift amount. 1: Use parameter M16 for grid shift amount.

    Range 0, 1 · Takes effect: At power on

  8. bit 7

    GL-axis specification

    0: Normal 1: GL-axis

    Range 0, 1 · Takes effect: At power on

Source

Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 79, 513, 514. Reference and explanation only — not a reproduction of the manual.