PARAMMachine parameter · FEED VEL. (M)
M23

FEED VEL. bit settings (2 bits)

Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
Bit settings — M23 is set bit by bit
  1. bit 0

    Selection of NC control axes/PLC control axes

    0: NC control axes 1: PLC control axes

    Range 0, 1 · Takes effect: At power on

  2. bit 1

    MP scale offset method

    Set the axis for which the MP scale offset method is adopted. 0: Normal 1: MP scale offset method

    Range 0, 1 · Takes effect: At power on

Source

Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 80, 515, 516. Reference and explanation only — not a reproduction of the manual.

Not sure what to set? Ask the Mazatrol assistant →