PARAMMachine parameter · FEED VEL. (M)
M41

Ram spindle stored stroke end, lower limit

Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
What it does

Ram spindle stored stroke end M40: Upper limit M41: Lower limit

For the machine specifications with a ram spindle, specify the maximum operating range for the ram spindle selection. When ram spindle is selected, the range specified in these parameters becomes the maximum operating range, instead of the manufacturer software limits specified in M08/M09.

Setting
Setting range±99999999
Unit0.0001 mm/0.0001°
Program typeM, E
Takes effectAfter stop of axis movement
Source

Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 80, 520. Reference and explanation only — not a reproduction of the manual.

Not sure what to set? Ask the Mazatrol assistant →