PARAMMachine parameter · FEED VEL. (M)
M41
Ram spindle stored stroke end, lower limit
Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
What it does
Ram spindle stored stroke end M40: Upper limit M41: Lower limit
For the machine specifications with a ram spindle, specify the maximum operating range for the ram spindle selection. When ram spindle is selected, the range specified in these parameters becomes the maximum operating range, instead of the manufacturer software limits specified in M08/M09.
Setting
Setting range±99999999
Unit0.0001 mm/0.0001°
Program typeM, E
Takes effectAfter stop of axis movement
Source
Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 80, 520. Reference and explanation only — not a reproduction of the manual.