PARAMMachine parameter · FEED VEL. (M)
M45

Selection of a door for signal input on the drive side (servo) in safety supervisory mode

Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
What it does

Selection of a door for signal input on the drive side (servo) in safety supervisory mode

Set which door signal is input for the axis with door signal input on the drive side (servo) in safety supervisory mode. 1: Door 1 signal 2: Door 2 signal 4: Door 3 signal 8: Door 4 signal

Setting
Setting range0 to 255
Unit—
Program typeM, E
Takes effectAt power on
Source

Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 80, 521. Reference and explanation only — not a reproduction of the manual.

Not sure what to set? Ask the Mazatrol assistant →