PARAMMachine parameter · FEED VEL. (M)
M66

Variable acceleration control: Cutting feed rate

Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
What it does

Variable acceleration control: Cutting feed rate

Set the cutting feed rate for variable acceleration control. When “0” is set, the value set at parameter L74 is assumed. [Related parameters] L74

Setting
Setting range0 to 255
Unitmm/min
Program typeM, E
Takes effectImmediate
Source

Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 80, 521. Reference and explanation only — not a reproduction of the manual.