PARAMMachine parameter · TIME CONST. (N)
N61
Real time tuning II Maximum inertia ratio
Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
What it does
Real time tuning II Maximum inertia ratio
Real time tuning II Maximum inertia ratio The optimum time constant is calculated from the estimated inertia ratio by setting the maximum and minimum values for the rapid feed time constant and inertia ratio. Rapid feed time constant N57 N60
Setting
Setting range0 to 65535
Unit%
Program typeM, E
Takes effectImmediate
Source