PARAMMachine parameter · TIME CONST. (N)
N63

Real time tuning II Rapid feed time constant, range of change

Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
What it does

Real time tuning II Rapid feed time constant, range of change

The current time constant is used if the difference between the optimum time constant and current time constant is equivalent to or smaller than the value set for N63, and the optimum time constant is used if the difference is greater than the value set for N63.

Setting
Setting range0 to 10000
Unitms
Program typeM, E
Takes effectImmediate