PARAMMachine parameter · TIME CONST. (N)
N66

Variable acceleration control: Cutting feed time constant

Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
What it does

Variable acceleration control: Cutting feed time constant

Set the cutting feed time constant for variable acceleration control. When “0” is set, the value set at parameter L75 is assumed. [Related parameters] L75

Setting
Setting range1 to 5000
Unitms
Program typeM, E
Takes effectImmediate
Source

Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 82, 532. Reference and explanation only — not a reproduction of the manual.