PARAMMachine parameter · ANOTHER (S)
S32

Rapid traverse speed for the mode of tool tip point control

Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
What it does

Rapid traverse speed for the mode of tool tip point control

The general setting for rapid traverse speed in parameter M1 will be used also for the mode of tool tip point control if it is lower than the setting in parameter S32. Note : Set zero (0) in S32 if it is desirable to use the general setting in parameter M1 for the rapid traverse in question.

Setting
Setting range0 to 200000
Unitmm/min (°/min)
Program typeE
Takes effectImmediate
Source

Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 84, 541. Reference and explanation only — not a reproduction of the manual.