ANOTHER bit settings (3 bits)
- bit 0
Non-target axis setting for indexing unit (rotational axis)
Non-target axis setting for indexing unit (rotational axis) Set the axis of which setting check or rotation command is not output in the indexing unit. * Rotational axis: the axis specified in parameter M17 bit 4 = 1 0: Target axis 1: Non-target axis Note : This is invalid for rotational axes of the sixth or higher. When parameter BA48 = 0 and L21 = 0, this is invalid for rotational axes of the fifth or higher.
- bit 1
Setting of an axis not displayed on the counter
Set an axis that is not displayed on the counter. 0 : Displayed 1 : Hidden
- bit 2
Rapid feed overlapping function disabled axis
Sets the disable axis for the rapid feed overlapping function. 0: Rapid feed overlapping function enabled axis 1: Rapid feed overlapping function disabled axis * When bit 2 of S45 is set to “1”, the settings of S49 and S50 will be ignored. S49 : Rapid feed overlapping function: G0 in-position width S50 : Rapid feed overlapping function: G1 in-position width
Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 84, 544, 545. Reference and explanation only — not a reproduction of the manual.