PARAMMachine parameter · ANOTHER (S)
S49
Rapid feed overlapping function: G0 in-position width
Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
What it does
Rapid feed overlapping function: G0 in-position width
Set the G0 in-position width to be used when the rapid feed overlapping function is valid. If a value outside the setting range is set, operation is carried out with the upper limit value (10000000) or lower limit value (0).
Setting
Setting range0 to 10000000
Unit—
Program typeM, E
Takes effectImmediate
Source
Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 84, 545. Reference and explanation only — not a reproduction of the manual.