PARAMMachine parameter · SPINDLE (SA)
SA133
Breakage detection torque for cutting-load detection pecking cycle
Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
What it does
Breakage detection torque for cutting-load detection pecking cycle
Set the detection torque to be used when the breakage detection distance (l) is specified for the cutting-load detection pecking cycle.
Setting
Setting range0 to 65535
Unit0.01 Nm
Program typeM, E
Takes effectImmediate
Source
Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 88, 566. Reference and explanation only — not a reproduction of the manual.