SPINDLE bit settings (7 bits)
- bit 0
Spindle winding coil selection function while override variable thread cutting is valid
0: Invalid 1: Valid
- bit 1
Spindle winding coil selection while override variable thread cutting is valid
0: H winding coil 1: L winding coil * This parameter is valid when bit 0 of parameter is set to 1.
- bit 3
Warning check for alarm 67 HI-SPEED SYNCTAP AXIS ALARM (for spindle C-axis)
0: Include 1: Do not include
- bit 4
Positive threading spindle rotational direction and encoder polarity
0: Spindle cycle counter increase 1: Spindle cycle counter decrease
- bit 5
Gear conversion during spindle rotation valid
- bit 6
Spindle gear changeover valid
- bit 7
Turret indexing valid