SPINDLE bit settings (7 bits)
- bit 0
Spindle speed range changing method, in relation to switching the torque factors for auto-pecking of the cutting load detection type
0: As specified by bit 1 1: L/H coil sw. + Mecha. gear shift * For the setting of SA45 bit 0 = 1, set the rated torque, viscous & coulomic friction coefficients of the spindle motor in the relevant parameters as tabulated below: Speed Rated Visc. fric. Coul. fric. range No. torque coef. coef.
- bit 1
Spindle speed range changing method, in relation to switching the torque factors for auto-pecking of the cutting load detection type 2
0: L/H coil switching scheme 1: Mecha-gear scheme (Only when 0 is set up at bit 0) * Bit 1 is valid only when bit 0 = 0.
- bit 2
Homing direction for synchronous tapping
- bit 3
Homing direction for synchronous tapping
00: Shorter route 01: Forward rotation 10: Reverse rotation
- bit 4
Defines the specified direction as the Z-phase detection direction
Defines the specified direction as the Z-phase detection direction.
- bit 5
Spindle index gear correction
0: Invalid 1: Valid
- bit 6
Selection of spindle removal
0: Invalid 1: Valid
Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 85, 551, 552, 553. Reference and explanation only — not a reproduction of the manual.