PARAMMachine parameter · SPINDLE (SA)
SA46
SPINDLE bit settings (8 bits)
Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
Bit settings — SA46 is set bit by bit
- bit 0
Direction of orientation
- bit 1
Direction of orientation
- bit 2
C-axis position control changeover type
- bit 3
Synchronous tapping position control changeover type
- bit 4
Z-phase detection direction
- bit 5
C-axis homing direction
- bit 6
C-axis homing direction
- bit 7
Synchronous tapping command polarity
Source
Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 85, 553. Reference and explanation only — not a reproduction of the manual.