PARAMMachine parameter · SPINDLE (SA)
SA93
Amount of synchronous tapping zero point shifting
Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
What it does
Amount of synchronous tapping zero point shifting
Set the amount of shifting from the Z-phase when the axis is to be returned to its zero point for synchronous tapping. Shifting is conducted in the Z-phase detection direction (specified in bit 4 of SA46).
Setting
Setting range0 to 359
Unit°
Program typeM, E
Takes effectAfter stop of movement
Source