PARAMMachine parameter · SPINDLE (SA)
SA94

Homing speed for synchronous tapping

Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
What it does

Homing speed for synchronous tapping

Set the homing speed effective when “After return to zero point” (SA46 bit 2 = 0) is selected as the position-changing type for synchronous tapping.

Setting
Setting range0 to 999999
Unitmin–1
Program typeM, E
Takes effectImmediate
Source

Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 87, 561. Reference and explanation only — not a reproduction of the manual.