PARAMMachine parameter · SPINDLE (SA)
SA99

Orientation time constant

Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
What it does

Orientation time constant

Set the time constant for orientation control. If 0 is set, 300 will be regarded as having been specified.

Setting
Setting range0 to 30000
Unitms
Program typeM, E
Takes effectAfter stop of movement
Source

Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 87, 562. Reference and explanation only — not a reproduction of the manual.

Not sure what to set? Ask the Mazatrol assistant →