PARAMUser parameter · SOLID (SD)
SD125-SD130

Table size SD125: Minimum table dimension X SD126: Maximum table dimension X SD127: Minimum table dimension Y SD128: Maximum table dimension Y SD129: Minimum table dimension Z SD130: Maximum table dimension Z

Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
What it does

Table size SD125: Minimum table dimension X SD126: Maximum table dimension X SD127: Minimum table dimension Y SD128: Maximum table dimension Y SD129: Minimum table dimension Z SD130: Maximum table dimension Z

< Round table > Table upper face direction is determined according to the setting of parameter SD51. 1. SD51 = 0: In the length in the Y-axis direction (SD127 + SD128) and that in the Z-axis direction (SD129 + SD130), the value having a smaller absolute value is taken as the diameter of the round table, and the length in the X-axis direction (SD125 + SD126) is taken as the height of the round table. The center of the rectangle (SD127, SD128, SD129, SD130) is taken as the center of the round table. 2. SD51 = 1: In the length in the X-axis direction (SD125 + SD126) and that in the Z-axis direction (SD129 + SD130), the value having a smaller absolute value is taken as the diameter of the round table, and the length in the Y-axis direction (SD127 + SD128) is taken as the height of the round table. The center of the rectangle (SD125, SD126, SD129, SD130) is taken as the center of the round table. 3. SD51 = 2: In the length in the X-axis direction (SD125 + SD126) and that in the Y-axis direction (SD127 + SD128), the value having a smaller absolute value is taken as the diameter of the round table, and the length in the Z-axis direction (SD129 + SD130) is taken as the height of the round table. The center of the rectangle (SD125, SD126, SD127, SD128) is taken as the center of the round table.  Vertical type (SD51 = 2)  Horizontal type (SD51 = 1)

Setting
Setting range0 to ±99999999
Unit0.0001 mm/0.00001 in
Program typeM, E
Takes effectImmediate
Source

Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 373, 374. Reference and explanation only — not a reproduction of the manual.

Not sure what to set? Ask the Mazatrol assistant →