PARAMUser parameter · SOLID (SD)
SD167
SOLID bit settings (2 bits)
Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
Bit settings — SD167 is set bit by bit
- bit 0
Display method for the jaws set on the 3D SETUP display in the turning mode
0: To be a solid of revolution 1: Not to be a solid of revolution
- bit 1
Sampling data automatic save function on occurrence of an INTELLIGENT SAFETY SHIELD (ISS) alarm
Source
Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 57, 376. Reference and explanation only — not a reproduction of the manual.