PARAMUser parameter · SOLID (SD)
SD50
Table type
Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
What it does
Table type
Select a table type for 3D setup display. 0: Square table 1: Round table 2: Chuck * When this parameter is set to “2” on machines with the vertical Z-axis (L110 bit 7 = 1) and the rotary head axis (BA48 ≠ 0), the table will be displayed by referring to the settings of parameters BA1 to BA3. With other machines, the chuck shape will not be displayed even if this parameter is set to “2”.
Setting
Setting range0 to 2
Unit—
Program typeM, E
Takes effectImmediate
Source
Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 56, 370. Reference and explanation only — not a reproduction of the manual.