PARAMUser parameter · SOLID (SD)
SD97
Distance of the model movement per time
Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
What it does
Distance of the model movement per time
Set the default value for the model’s movement distance per time that is to be displayed in the movement distance assignment dialog box.
Setting
Setting range0 to 99999999
Unit0.0001 mm/0.00001 in
Program typeM, E
Takes effectImmediate
Source
Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 372. Reference and explanation only — not a reproduction of the manual.