PARAMUser parameter · SOLID (SD)
SD98
Amount of model rotation per time
Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
What it does
Amount of model rotation per time
Set the default value for the amount of model rotation per time that is to be displayed in the amount-of-rotation assignment dialog box.
Setting
Setting range0 to 3600000
Unit0.0001°
Program typeM, E
Takes effectImmediate
Source
Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 57, 372. Reference and explanation only — not a reproduction of the manual.