PARAMUser parameter · SYSTEM (SU)
SU110-SU113

Tool length setting range check function Settable data range SU110 Max. tool length (+X-axis) SU111 Min. tool length (–X-axis) SU112 Max. tool length (+Z-axis) SU113 Min. tool length (–Z-axis)

Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
What it does

Tool length setting range check function Settable data range SU110 Max. tool length (+X-axis) SU111 Min. tool length (–X-axis) SU112 Max. tool length (+Z-axis) SU113 Min. tool length (–Z-axis)

Set the desired data range. Note : Although entered data is checked for the range that has been set in - SU113, the check is conducted only when the “Tool length setting range check function” is valid (SU154 bit 1 = 1). Example of setting (SU111 = 0):

Setting
Setting range±19999999
Unit0.0001 mm/0.00001 in
Program typeM
Takes effectImmediate
Source

Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 300. Reference and explanation only — not a reproduction of the manual.

Not sure what to set? Ask the Mazatrol assistant →