PARAMUser parameter · SYSTEM (SU)
SU135
Acceleration/deceleration time constant during chopping
Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
What it does
Acceleration/deceleration time constant during chopping
Set the acceleration/deceleration time constant during chopping. When this parameter is set to 0, parameter N2 becomes valid.
Setting
Setting range0 to 5000
Unitms
Program typeE
Takes effectImmediate
Source
Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 48, 304. Reference and explanation only — not a reproduction of the manual.