PARAMUser parameter · SYSTEM (SU)
SU154

SYSTEM bit settings (8 bits)

Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
Bit settings — SU154 is set bit by bit
  1. bit 0

    Displaying tool-setting values for ATC-type turret

    0: Do not display 1: Display

    Range 0, 1 · Takes effect: Immediate

  2. bit 1

    Tool length setting range check function

    0 : Invalid 1 : Valid

    Range 0, 1 · Takes effect: Immediate

  3. bit 2

    Displaying the “next distance” during execution of G18.2/G18.3/G18.4

    0: Actual axis 1: Virtual axis

    Range 0, 1 · Takes effect: Immediate

  4. bit 3

    Displaying the “remaining distance” during execution of G18.2/G18.3/G18.4

    0: Actual axis 1: Virtual axis

    Range 0, 1 · Takes effect: Immediate

  5. bit 4

    Displaying the “current position” during execution of G18.2/G18.3/G18.4

    0: Actual axis 1: Virtual axis

    Range 0, 1 · Takes effect: Immediate

  6. bit 5

    Display of BUFFER during G17.1 - G17.5 mode

    0: Actual axis 1: Virtual axis

    Range 0, 1 · Takes effect: Immediate

  7. bit 6

    Display of REMAIN during G17.1 - G17.5 mode

    0: Actual axis 1: Virtual axis

    Range 0, 1 · Takes effect: Immediate

  8. bit 7

    Display of POSITION during G17.1 - G17.5 mode

    0: Actual axis 1: Virtual axis

    Range 0, 1 · Takes effect: Immediate

Source

Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 48, 307, 308, 309. Reference and explanation only — not a reproduction of the manual.