PARAMUser parameter · SYSTEM (SU)
SU159

SYSTEM bit settings (1 bit)

Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
Bit settings — SU159 is set bit by bit
  1. bit 1

    Selection of whether or not to consider the tool length for tip position memory on the WORK OFFSET display

    0: Whether or not to consider tool length depends on bit 3 of parameter F93. Do not consider tool length when bit 3 of parameter F93 is set to 0. Consider tool length when bit 3 of parameter F93 is set to 1. 1: Do not consider tool length. * F93 (bit 3) Tool length in MAZATROL tool data in the EIA/ISO program (0: invalid, 1: valid)

    Range 0, 1 · Takes effect: Immediate

Source

Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 49, 316. Reference and explanation only — not a reproduction of the manual.

Not sure what to set? Ask the Mazatrol assistant →