PARAMUser parameter · SYSTEM (SU)
SU22

Method of axis movement from the initial point or the escape TPC relay point to the rotating position in the indexing unit

Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
What it does

Method of axis movement from the initial point or the escape TPC relay point to the rotating position in the indexing unit

Initial-point scheme Initial point SU22 = 0 SU22 = 2 position in the Z TPC relay point Material scheme Machining end SU22 = 2 position TPC relay point

Setting
Setting range0 to 2
Unit—
Program typeM
Takes effectImmediate
Source

Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 46, 291, 292. Reference and explanation only — not a reproduction of the manual.

Not sure what to set? Ask the Mazatrol assistant →