PARAMUser parameter · SYSTEM (SU)
SU24
Spindle speed multiplication factor in the execution of a composite-type fixed cycle
Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
What it does
Spindle speed multiplication factor in the execution of a composite-type fixed cycle
Set the spindle speed multiplication factor for the execution of a composite-type fixed cycle. The setting “0” is regarded as a setting of 100%.
Setting
Setting range0 to 255
Unit%
Program typeE
Takes effectImmediate
Source
Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 46, 293. Reference and explanation only — not a reproduction of the manual.