PARAMUser parameter · SYSTEM (SU)
SU55

Wait time for accessing the programs in the hard disk operation area/Ethernet operation area

Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
What it does

Wait time for accessing the programs in the hard disk operation area/Ethernet operation area

Sets the wait time for the response to a request to access the programs in the hard disk operation area and Ethernet operation area in automatic operation 0: Continues to wait for the response to an access request 1 to 65535: Displays the alarm 1835 FILE ACCESS ERROR ( , , ) if no response is received within the set wait time after requesting Note : 1. Set the parameter for system 1. 2. Normally, an access to a program is completed within one second. Since the purpose of this parameter is to detect a wait for a response, set a value of 10 or larger when changing the setting of this parameter. If a value less than 10 is set, the alarm 1835 FILE ACCESS ERROR ( , , ) may occur before completion of normal processing.

Setting
Setting range0 to 65535
Unit—
Program typeE
Takes effectImmediate
Source

Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 47, 296. Reference and explanation only — not a reproduction of the manual.

Not sure what to set? Ask the Mazatrol assistant →