PARAMUser parameter · SYSTEM (SU)
SU9
Axis setting K for plane selection
Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
What it does
Axis setting K for plane selection
For details, refer to the explanation of parameters SU1 to SU3.
Setting
Setting range0 to 255
Unit—
Program typeM, E
Takes effectAfter stop of movement
Source