Lower-turret retraction function Fixed point of the retraction position

Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
What it does

Lower-turret retraction function Fixed point of the retraction position

Set the position where the turret is to be retracted for the turret retraction function. Specify coordinates in the machine coordinate system based on the machine zero point. SU97 SU97: X-axis retraction point – Fixed point 1 SU98: Z-axis retraction point – Fixed point 1 SU99: X-axis retraction point – Fixed point 2 SU100: Z-axis retraction point – Fixed point 2 Specify a minus value if the fixed point of the retraction position is located in a minus direction when viewed from the zero point of the machine coordinates. Note : Set this parameter for the system of the lower turret.

Setting
Setting range0 to 99999999
Unit0.001 mm/0.0001 in
Program typeM
Takes effectImmediate
Source

Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 297. Reference and explanation only — not a reproduction of the manual.