Lower-turret retraction function Fixed point of the retraction position
Lower-turret retraction function Fixed point of the retraction position
Set the position where the turret is to be retracted for the turret retraction function. Specify coordinates in the machine coordinate system based on the machine zero point. SU97 SU97: X-axis retraction point – Fixed point 1 SU98: Z-axis retraction point – Fixed point 1 SU99: X-axis retraction point – Fixed point 2 SU100: Z-axis retraction point – Fixed point 2 Specify a minus value if the fixed point of the retraction position is located in a minus direction when viewed from the zero point of the machine coordinates. Note : Set this parameter for the system of the lower turret.
Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 297. Reference and explanation only — not a reproduction of the manual.