PARAMData I/O parameter · TAPE (TAP)
TAP5
DC code parity
Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
What it does
DC code parity
This parameter is used to specify whether or not a parity bit is to be assigned to the DC code to be output. Set values Parity Hole-punching pattern of DC3 code 0 No assignment 1 Assignment Note : This parameter is valid only when HAND SHAKE is set to DC CONTROL.
Setting
Setting range0, 1
Unit—
Program typeM, E
Takes effectAt I/O startup
Source