PARAMData I/O parameter · TAPE (TAP)
TAP6

Feed section DC code output

Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
What it does

Feed section DC code output

Select whether or not DC2 and DC4 codes are to be output to the feed sections which will be generated at the beginning and end of paper tape punching. Example : : 0 Neither DC2 nor DC4 is output. 3 Both DC2 and DC4 are output. Note : This parameter is valid only when HAND SHAKE is set to DC CONTROL.

Setting
Setting range0 to 3
Unit—
Program typeM, E
Takes effectAt I/O startup
Source

Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 96, 614. Reference and explanation only — not a reproduction of the manual.