PARAMUser parameter · TURNING (TC)
TC141

Use/disuse of acceleration in up-going slope during rough cutting cycle in bar machining unit

Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
What it does

Use/disuse of acceleration in up-going slope during rough cutting cycle in bar machining unit

F F : F e e d rate for rough (TC2, TC3)

Setting
Setting range0, 1
Unit—
Program typeM
Takes effectImmediate
Bit settings — TC141 is set bit by bit
  1. bit 0

    Use/disuse of acceleration in up-going slope during rough cutting cycle in bar machining unit

    Takes effect: Immediate

  2. bit 1

    Use/disuse of deceleration in down-going slope during rough cutting cycle in bar machining unit

    F F : F e e d ra te f o r rough c u t ti n g c yc l e (TC5, TC6)

    Range 0, 1 · Takes effect: Immediate

  3. bit 2

    Selection between use/disuse of acceleration distance check at start of thread cutting unit

    Alarm not caused even if acceleration distance at start of thread cutting unit exceeds clamp data Alarm caused when acceleration distance at start of thread cutting unit exceeds clamp data Example : L : Acceleration distance clamp data (TC77)

    Range 0, 1 · Takes effect: Immediate

  4. bit 3

    Selection between start position shift/start angle shift for thread number offset in thread cutting unit

    (bit 3) = 0: Start position shift Thread number offset adjusted by moving thread cutting start position 2nd thread changes according to the (bit 3) = 1: Start angle shift Thread number offset adjusted according to thread cutting start angle

    Range 0, 1 · Takes effect: Immediate

  5. bit 5

    Selecting an angle margin for nose shape compensation

    An angle margin for nose shape compensation can be selected by setting data in bits 4 and 5. Bit 5 Bit 4 shape compensation

    Range 0, 1 · Takes effect: Immediate

  6. bit 6

    CHUCK JAW DATA display name/code selection

    A code can be selected. A name can be selected.

    Range 0, 1 · Takes effect: Immediate

  7. bit 7

    Whether to make the partition plate and the workpiece barrier valid

    Partition plate and the workpiece barrier valid Partition plate and the workpiece barrier invalid

    Range 0, 1 · Takes effect: Immediate

Source

Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 53, 54, 350, 351. Reference and explanation only — not a reproduction of the manual.

Not sure what to set? Ask the Mazatrol assistant →