TURNING bit settings (7 bits)
- bit 0
Modal condition about diameter/radius value input for the unit succeeding a manual program or subprogram unit
0: The condition of the manual program or subprogram unit is retained. 1: The condition of the unit preceding a manual program or subprogram unit is used.
- bit 1
Z/C offset value to be used in the EIA/ISO subprogram after workpiece transfer in the MAZATROL program
Z/C offset value to be used in the EIA/ISO subprogram after workpiece transfer in the MAZATROL program 0: Z/C offset value set in the workpiece transfer unit 1: Z/C offset value for the MAZATROL program set on the SET UP MANAG. display
- bit 3
Tool change position at RETURN in end unit when FLASH tool is mounted
0: FLASH tool change position (TC62) 1: Tool change position (SU10)
- bit 4
Whether pressing is to be made selectable for workpiece transfer units of a BAR moving pattern
Whether pressing is to be made selectable for workpiece transfer units of a BAR moving pattern. 0: Not to be made selectable 1: To be made selectable
- bit 5
Tool nose position of an inside-turning grooving tool for machining on the back side
0: Upper right corner of the tip-width section 1: Upper left corner of the tip-width section (compatible with M640T, MT, T NEXUS, and MT Pro)
- bit 6
Handling of nose R in the retraction path during grooving #4, 5 (cutting off)
0: Include nose R. (MTPro compatible) 1: Do not include nose R.
- bit 7
Z-axial withdrawal after M-code unit execution
Z-axial withdrawal after M-code unit execution when the tool nose is positioned at the edge clearance including the workpiece edge protrusion (See example below.) 0: Invalid 1: Valid Example : The tool will be withdrawn after execution of the M-code unit when the tool nose has been positioned in the area between the front clearance point and the workpiece zero point (the hatched section in the figure) using the manual program unit, or when the program is restarted from the M-code unit with the tool nose positioned in that area. Note : bit 1 is valid only when F161 bit 7 is set to 1.
Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 55, 358, 359. Reference and explanation only — not a reproduction of the manual.