PARAMUser parameter · TURNING (TC)
TC158

Feed rate override in reciprocating grooving operation

Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
What it does

Feed rate override in reciprocating grooving operation

Sets the override for the traverse feed rate in reciprocating grooving operation. Setting “0” results in the same operation as when “100” is set.

Setting
Setting range0 to 200
Unit%
Program typeM
Takes effectImmediate
Source

Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 56, 365. Reference and explanation only — not a reproduction of the manual.