PARAMUser parameter · TURNING (TC)
TC35

Lower limit for thrust ratio

Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
What it does

Lower limit for thrust ratio

Sets the lower limit for the ratio of the workpiece pressing thrust for CHUCK and BAR units. If a value smaller than the one set for this parameter is set for the CHUCK or BAR workpiece pressing thrust of the workpiece transfer unit of a MAZATROL program, the alarm 402 ILLEGAL NUMBER INPUT will be generated. If the workpiece pressing thrust specified for #3030 in an EIA/ISO program, the alarm 1144 MISSING TRANSFER (PUSH THRUST) will be generated.

Setting
Setting range0 to 100
Unit%
Program typeM, E
Takes effect—
Source

Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 51, 326. Reference and explanation only — not a reproduction of the manual.

Not sure what to set? Ask the Mazatrol assistant →