PARAMUser parameter · TURNING (TC)
TC66

Minimum index angle of the FLASH tool

Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
What it does

Minimum index angle of the FLASH tool

This parameter is used as the basis for judging whether the index angle entered in TOOL DATA display is acceptable. An alarm will be displayed if the entered value is judged to be unacceptable. (Specify “900” for 4-segment splitting.)

Setting
Setting range0 to 3599
Unit0.1°
Program typeM, E
Takes effectImmediate
Source

Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 52, 338. Reference and explanation only — not a reproduction of the manual.

Not sure what to set? Ask the Mazatrol assistant →