PARAMUser parameter · DISPLAY STRUCTURE (US)
US1

DISPLAY STRUCTURE bit settings (7 bits)

Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
Bit settings — US1 is set bit by bit
  1. bit 0

    Menu highlighting method

    Selects the highlighting method for the menu items selected. 0: Display the frame and text in green 1: Display the background in white and text in black

    Range 0, 1 · Takes effect: Immediate

  2. bit 1

    Selection of operation for automatic determination of cutting conditions when tool data is not input

    Select the operation to be performed when tool data (ACT-, NOSE-R, EDG-ANG, TIP-WID, WIDTH) is not input upon automatically determining cutting conditions. 0: Displaying the alarm 414 AUTO CALCULATION IMPOSSIBLE 1: Automatically determining cutting conditions by referring to NOM- in the program and parameters US43, US44, US45 and US46

    Range 0, 1 · Takes effect: Immediate

  3. bit 2

    MAZA-CHECK input support function log output, parameter reference

    0: Fixed for each machine model 1: According to the setting file

    Range 0, 1 · Takes effect: Immediate

  4. bit 3

    Status of [TOP CUT FIRST] when the power is turned on

    Status of [TOP CUT FIRST] when the power is turned on at the BF SCHEDULE/IBL SCHEDULE display 0: Enabled (The top cut program is executed upon starting scheduled operation.) 1: Disabled (The top cut program is not executed upon starting scheduled operation.)

    Range 0, 1 · Takes effect: At power on

  5. bit 4

    Directory selection function in the WORK No. SELECT window

    0: Invalid 1: Valid

    Range 0, 1 · Takes effect: Immediate

  6. bit 5

    Project function in the WORK No. SELECT window/PROGRAM FILE display

    0: Invalid 1: Valid

    Range 0, 1 · Takes effect: Immediate

  7. bit 6

    Alarm window display selection while displaying Smooth application manager

    Display of the alarm window while the Smooth application manager is displayed 0 : Not displayed 1 : Displayed

    Range 0, 1 · Takes effect: Immediate

Source

Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 57, 377, 378. Reference and explanation only — not a reproduction of the manual.

Not sure what to set? Ask the Mazatrol assistant →