PARAMUser parameter · DISPLAY STRUCTURE (US)
US37

Data guard function: Maximum number of users

Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
What it does

Data guard function: Maximum number of users

Set the number of users which the data guard function identifies. * The function is invalid when “0” or “1” is set.

Setting
Setting range0 to 8
Unit—
Program typeM, E
Takes effectAt power on
Source

Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 57, 378. Reference and explanation only — not a reproduction of the manual.

Not sure what to set? Ask the Mazatrol assistant →